    PLC00x-G2 Configurator 
      -     ;
	  -      (Steps Per Unit, Velocity, Acceleration);
      - ,        ;
	  -             

    
               ()
            
     

--------------------------------------------------------------------------------------------------------------------------------------------------------------
       :
		1.        ( SW1-SW4   ON).      ;
		2.    ;
		3.   (VCP_V1.4.0_Setup.exe);
		4.      COM     ;
		5.  .     ,         PLC00x;
		6.       "".            ;
		7.            G-Code   ;
		8.      G-Code          ;
		9.      :
			a)      Steps per, Velocity Acceleration.  ""    ;
			b)      ,          ;
			c)   " G-CODE"      .      .

			   

--------------------------------------------------------------------------------------------------------------------------------------------------------------
     

	A+10		-     100 
	A+200, F100	-     200    100/min
	A-250		-     250 
	A-100, F50	-     100    50/min

	PAUSE 		-   (   Play)
 	PAUSE 1000	-  1000  ( 1 ),    1  60000

	M0		-  

	M47		-   

	M511		-      INP1 =1
	M512		-      INP2 =1
	M513		-      INP3 =1

	M521		-      INP1 =1
	M522		-      INP2 =1
	M523		-      INP3 =1

	M530		-   enabled

   	FAST		-      M511-523

	M541		-    INP1 =1
	M542		-    INP2 =1
	M543		-    INP3 =1

	M551		-    INP1 =1  INP2 =1
	M552		-    INP2 =1  INP3 =1
	M553		-    INP3 =1  INP1 =1 	

	M561		-    INP2 =1   INP1 =1 
	M562		-    INP3 =1   INP2 =1
	M563		-    INP1 =1   INP3 =1

	M571		-   R1 
	M572		-   R1 
	M581		-   R2 
	M582		-   R2 

	601  		-      INP1 =0    STRING
	602  		-      INP2 =0    STRING
	603  		-      INP3 =0    STRING

	611  		-      INP1 =1    STRING
	612  		-      INP2 =1    STRING
	613  		-      INP3 =1    STRING

	STRING		-       M601-M613

	GOTO xx		-    

	M711		-      INP1
	M712		-      INP2
	M713		-      INP3

	M721		-      INP1
	M722		-      INP2
	M723		-      INP3


--------------------------------------------------------------------------------------------------------------------------------------------------------------
	 1 -   ,    INP1  INP2   
	 ->    ->      INP2 ->       INP1 -> 

	01- M521, F500 -       F500 (  )
	02- M571 -   R1 
	03- M512 -     INP2				
	04- M572 -   R1
	05- M581 -   R2
	06- M521 -     INP1
	07- M582 -   R2
	08- GOTO 2 -    2

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
	 2
	 ->    ->    INP2 ->     100  ->     90  ->    1

	01- M521, F500
	02- M542 
 	03- A+100
	04- A-90
	05- GOTO 1
	
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
	 3 
	 ->    ->    INP3    INP2 ->     100  ->     90  ->    1

	01- M521, F500
	02- M552 
 	03- A+100
	04- A-90
	05- GOTO 1



- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
	 4
	 ->    INP2    10 ->    INP3    20 , 10-      INP1 , 20-      INP2 

	01- M612, STRING 10
	02- M613, STRING 20
	03- PAUSE 250
	04- M530
	05- GOTO 1
	06- 
	07-
	08-
	09-
	10- M711
	11- GOTO 1
	12-
	13-
	14-
	15-
	16-
	17-
	18-
	19-
	20- M721
	21- GOTO 1

--------------------------------------------------------------------------------------------------------------------------------------------------------------
           (   )

      "A1"  "A+1"	-    1 
      "A2, F100"    	-    2    100 (100 /min    Steps per    Velocity)    
      "A-100, F10"    	-    100    10 /min
      "STEP 800"	-   800   (  60000) 
      "STEP -100"	-   100   (  60000)      

--------------------------------------------------------------------------------------------------------------------------------------------------------------